Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.11765/11631
Almost one year of TROPOMI/S5P total ozone column data: global ground-based validation
Título : Almost one year of TROPOMI/S5P total ozone column data: global ground-based validation
Autor : Garane, KaterinaBalis, DimitrisKoukouli, Maria-ElissavetBais, Alkiviadis F.Fioletov, VitaliPazmino, AndreaLambert, Jean-ChristopherVerhoelst, TijlGranville, JoseBazureau, ArianeGoutail, FlorencePommereau, Jean-PierreMcLinden, ChrisHeue, Klaus-PeterLoyola, DiegoXu, JianZimmer, WalterRomahn, FabianLerot, ChristopheRoozendael, Michel VanRedondas, Alberto ORCID RESEARCHERID Autor AEMETZerefos, Christos S.
Palabras clave : Ozone column; Brewer measurements; Tropospheric Monitoring Instrument
Fecha de publicación : 2018
Citación : ATMOS 2018
Versión del editor: https://dx.doi.org/10.13140/RG.2.2.23528.72962
Resumen : In this work we present the validation results of almost one year of TROPOMI Near Real Time (NRTI) and OFFLine (OFFL) data against ground-based quality-assured Brewer and Dobson total ozone column (TOC) measurements deposited in the World Ozone and Ultraviolet Radiation Data Center (WOUDC). Additionally, comparisons to Brewer measurements from the European Brewer Network (EUBREWNET) and the Canadian Network are performed, as well as to twilight zenith-sky measurements obtained with ZSL-DOAS (Zenith Scattered Light Differential Optical Absorption Spectroscopy) instruments, that form part of the SAOZ network (Système d'Analyse par Observation Zénitale) of the Network for the Detection of Atmospheric Composition Change (NDACC). Through the comparison of the TROPOMI measurements to the total ozone ground-based measurements from stations that are distributed globally, as the background truth, the dependence of the new instrument on latitude, cloud properties, solar zenith and viewing angles, among others, is examined. Validation results show that the mean bias and the standard deviation of the percentage difference between TROPOMI and QA ground TOC meet the product requirements.
Descripción : Póster presentado en: ATMOS 2018, celebrado en Salzburgo (Austria) del 26 al 29 de noviembre de 2018.
URI : http://hdl.handle.net/20.500.11765/11631
Colecciones: Otros póster


Ficheros en este ítem:
  Fichero Descripción Tamaño Formato  
Almost_one_year_TROPO...
2,47 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo del ítem



Los ítems de Arcimis están protegidos por una Licencia Creative Commons, salvo que se indique lo contrario.

Repositorio Arcimis
Nota Legal Contacto y sugerencias