Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.11765/12386
The REDMAAS 2014 intercomparison campaign: CPC, SMPS, UFPM and neutralizers
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGómez Moreno, Francisco Javieres_ES
dc.contributor.authorAlonso Blanco, Elisabethes_ES
dc.contributor.authorArtíñano, Begoñaes_ES
dc.contributor.authorIglesias Samitier, Silviaes_ES
dc.contributor.authorPiñeiro Iglesias, Maríaes_ES
dc.contributor.authorLópez Mahía, Purificaciónes_ES
dc.contributor.authorPérez, Noemíes_ES
dc.contributor.authorAlastuey, Andréses_ES
dc.contributor.authorMorena Carretero, Benito A. de laes_ES
dc.contributor.authorGarcía, María Isabeles_ES
dc.contributor.authorRodríguez González, Sergioes_ES
dc.contributor.authorSorribas, Mares_ES
dc.contributor.authorTitos Vela, Gloriaes_ES
dc.contributor.authorLyamani, Hassanes_ES
dc.contributor.authorAlados Arboledas, Lucases_ES
dc.contributor.authorFilimundi, E.es_ES
dc.contributor.authorLatorre Tarrasa, Enriquees_ES
dc.date.accessioned2020-09-02T08:50:55Z-
dc.date.available2020-09-02T08:50:55Z-
dc.date.issued2014-
dc.identifier.citationRosell-Llompart, Joan , Grifoll, Jordi (eds.). 2n Iberian Meeting on Aerosol Science and Technology: proceedings. Tarragona: Universitat Rovira i Virgili, 2014, p. 127-131es_ES
dc.identifier.isbn978-84-695-9978-5-
dc.identifier.urihttp://hdl.handle.net/20.500.11765/12386-
dc.descriptionPonencia presentada en:2nd Iberian Meeting on Aerosol Science and Technology (RICTA 2014) celebrado en Tarragona del 7 al 9 de julio de 2014.es_ES
dc.description.abstractThe Spanish network on environmental DMAs (Red Española de DMAs Ambientales, REDMAAS), working since 2010, is currently formed by six groups involved in the measurement of atmospheric aerosol size distributions by means of Differential Mobility Analyzers (DMAs). One of its activities is an annual intercomparison of mobility size spectrometers (SMPS and UFPM). In this work we show the results obtained in the 2014 campaign: the verification of DMA calibrations with latex, the results of the CPC and SMPS + UFPM intercomparisons, and a comparison of the new TSI 3087 X-ray and the former TSI 3077 85Kr neutralizers. The concentrations measured by different types of CPC were within the range of 10% of the average value. CPCs working at higher flow rates measured slightly higher concentrations, probably related to the smaller losses in the lines. All the SMPS worked at the same sampling and sheath flow rates (1:10 lpm). Four of the SMPS gave very good results for particles larger than 20 nm. The UFPM measured particle number concentrations in the average +/-10% band measured by the SMPS. Instruments working with the X-ray neutralizer measured higher concentrations than with the 85Kr neutralizers. This could mean that particle losses are smaller inside this neutralizer.es_ES
dc.description.sponsorshipThis work has been financed by the Ministry of Science and Innovation (CGL2011-15008-E, CGL2010-1777, CGL2011-27020 & CGL2011-26259).es_ES
dc.language.isoenges_ES
dc.publisherUniversitat Rovira i Virgilies_ES
dc.rightsLicencia CC: Reconocimiento-NoComercial-CompartirIgual CC BY-NC-SAes_ES
dc.subjectAtmospheric aerosolses_ES
dc.subjectParticle size distributiones_ES
dc.subjectSMPSes_ES
dc.subjectUFPMes_ES
dc.subjectX-ray neutralizeres_ES
dc.titleThe REDMAAS 2014 intercomparison campaign: CPC, SMPS, UFPM and neutralizerses_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
Colecciones: Otras actas-congresos


Ficheros en este ítem:
  Fichero Descripción Tamaño Formato  
REDMAAS_2014_GomezMor...
573,94 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro sencillo del ítem



Los ítems de Arcimis están protegidos por una Licencia Creative Commons, salvo que se indique lo contrario.

Repositorio Arcimis
Nota Legal Contacto y sugerencias