Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.11765/14300
Intercomparison of the NO2 vertical column densities measured over Izaña with two ground-based remote sensing techniques: DOAS and FTIR
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRobles González, Cristinaes_ES
dc.contributor.authorNavarro Comas, Mónicaes_ES
dc.contributor.authorPuentedura, Olgaes_ES
dc.contributor.authorHase, Frankes_ES
dc.contributor.authorSchneider, Matthiases_ES
dc.contributor.authorCuevas Agulló, Emilioes_ES
dc.contributor.authorGil-Ojeda, Manueles_ES
dc.date.accessioned2023-01-12T11:38:57Z-
dc.date.available2023-01-12T11:38:57Z-
dc.date.issued2013-
dc.identifier.citationFernández-Renau González-Anleo, Alix, Miguel Llanes, Eduardo de (Eds.). Teledetección: sistemas operacionales de observación de la Tierra. [Madrid]: Asociación Española de Teledetección, 2013es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.11765/14300-
dc.descriptionPonencia presentada en: XV Congreso de la Asociación Española de Teledetección celebrado en Torrejón de Ardoz (Madrid), del 22 al 24 de octubre de 2013.es_ES
dc.description.abstract[ES]En el marco del proyecto NORS se ha realizado una intercomparación de medidas de NO2 con dos técnicas de detección remota desde superficie: DOAS y FTIR. Las columnas verticales de NO2 medidas en Izaña por dos espectrómetros de alta calidad como son el RASAS basado en la técnica DOAS y el instrumento comercial BRUKER-120 basado en la técnica FTIR, han sido comparadas. Debido a la fuerte variación fotoquímica del NO2, las medidas realizadas con el FTIR han sido corregidas con un Box-model fotoquímico para referenciarlas a la hora de medida del RASAS. Los resultados de ambos instrumentos se comparan bien, dando unas diferencias medias de 7±18%.es_ES
dc.description.abstract[EN]In the frame of the NORS Project, an intercomparison exercise of two ground-based remote sensing techniques is presented: DOAS and FTIR. Results form two high quality spectrometers located at the Izaña Atmospheric Observatory are shown and compared. DOAS based instruments are two RASAS, developed at INTA, working in the UV-VIS part of the spectrum. FTIR based instrument is a Bruker-120 that measures in the IR. To account for the NO2 strong photochemical variation a Box-model has been used to refer the FTIR data to the DOAS measurement time. Results show a good agreement in the NO2 concentrations. Mean differences are of 7±18%.es_ES
dc.description.sponsorshipThe work described in this paper is partially supported by the NORS project under the funding of the European Community's Seventh Framework Programme ([FP7/2007-2013]) under grant agreement n°284421 and by the AMISOC project (CGL2011-24891) under the funding of the Spanish Ministry of Economy and Competitiveness (MINECO).es_ES
dc.language.isoenges_ES
dc.publisherAsociación Española de Teledetecciónes_ES
dc.subjectNO2es_ES
dc.subjectDOASes_ES
dc.subjectFTIRes_ES
dc.subjectNORSes_ES
dc.titleIntercomparison of the NO2 vertical column densities measured over Izaña with two ground-based remote sensing techniques: DOAS and FTIRes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/284421es_ES
Colecciones: Congresos AET (Asociación Española de Teledetección)