Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.11765/9155
Posibles causas de flujos diurnos negativos de vapor de agua en el verano en Barcelona
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Tejeda Martínez, Adalberto | es_ES |
dc.contributor.author | Utrera Zárate, Alberto | es_ES |
dc.contributor.author | García Tello, Luis G. | es_ES |
dc.contributor.author | Jáuregui, Ernesto | es_ES |
dc.contributor.author | Zarraluqui, Víctor | es_ES |
dc.contributor.author | Moreno García, Mª Carmen | es_ES |
dc.date.accessioned | 2018-05-22T11:46:17Z | - |
dc.date.available | 2018-05-22T11:46:17Z | - |
dc.date.issued | 2002 | - |
dc.identifier.citation | Guijarro Pastor, J.A. (Ed.). El agua y el clima. España: Publicaciones de la Sociedad Española de Climatología, 2002, p. 357-366 | es_ES |
dc.identifier.isbn | 84-7632-757-9 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.11765/9155 | - |
dc.description | Ponencia presentada en: III Congreso de la Asociación Española de Climatología “El agua y el clima”, celebrado en Palma de Mallorca del 16 al 19 de junio de 2002. | es_ES |
dc.description.abstract | [ES]Del 16 al 21 de junio del 2001 se realizaron mediciones de balance energético atmosférico en el centro de la ciudad de Barcelona. Los flujos de calor latente y de calor sensible se obtuvieron con el método de covarianza turbulenta a partir de datos instantáneos tomados a 20 Hz y procesados cada media hora. Los comportamientos del balance responden a lo esperado bajo estabilidad atmosférica. Sin embargo, se presentaron casos de flujos turbulentos de calor latente de evaporación (QE) negativos (hacia abajo) a mitad del día. Aquí se discute el tratamiento de esos casos bajo dos hipótesis: a) Eventuales fallas del equipo de medición, b) Se analizan casos de QE negativo para una situación meteorológica similar en la ciudad de México, con datos instantáneos tomados cada segundo. Aún para el día se encontraron rachas de subsidencia, que pueden generar flujos netos negativos de vapor de agua. | es_ES |
dc.description.abstract | [EN]Atmospheric energy balance measurements were made from 06/16/2001 to 06/21/2001 in downtown Barcelona, Spain. The latent and sensible turbulent heat fluxes were obtained using eddycovariance method. The data were taken at 20 Hz and processed every 30 minutes. Actually, the behavior of energy balance components was as expected to an urban zone with oceanic influence under atmospheric stability conditions. However, negative latent heat fluxes (down direction) were presented in some times around midday. This paper shows the analysis of these cases according to two hypotheses: a) If there were instrumental errors, b) For similar meteorological situation in Mexico City, the QE negative values were analyzed, but from instantaneous data from vertical wind and specific humidity sensed each second. It was found that subsidence cases were presented during day- time, too. | es_ES |
dc.language.iso | spa | es_ES |
dc.relation.ispartof | Publicaciones de la Asociación Española de Climatología. Serie A ; 3 | es_ES |
dc.rights | Licencia CC: Reconocimiento–NoComercial–SinObraDerivada CC BY-NC-ND | es_ES |
dc.subject | Vapor de agua | es_ES |
dc.subject | Subsidencia | es_ES |
dc.subject | Water vapor | es_ES |
dc.subject | Subsidence | es_ES |
dc.title | Posibles causas de flujos diurnos negativos de vapor de agua en el verano en Barcelona | es_ES |
dc.type | info:eu-repo/semantics/conferenceObject | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
Colecciones: | (2002, Palma de Mallorca). III Congreso AEC |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | ||
---|---|---|---|---|---|
0037_PU-SA-III-2002-A... | 1,06 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de Arcimis están protegidos por una Licencia Creative Commons, salvo que se indique lo contrario.