Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.11765/11531
Temperature dependence of the Brewer global UV measurements
Título : Temperature dependence of the Brewer global UV measurements
Autor : Fountoulakis, IliasRedondas, AlbertoLakkala, KaisaBerjón, AlbertoBais, Alkiviadis F.Doppler, LionelFeister, UweHeikkilä, AnuKarppinen, TomiKarhu, Juha MattiKoskela, TapaniGarane, KaterinaFragkos, KonstantinosSavastiouk, Vladimir
Palabras clave : Spectral UV; Brewer spectrophotometers; Temperature correction factors
Fecha de publicación : 2017
Editor: European Geosciences Union
Citación : Atmospheric Measurement Techniques. 2017, 10(11), p. 44491–4505
Versión del editor: https:/dx./doi.org/10.5194/amt-10-4491-2017
Resumen : Spectral measurements of global UV irradiance recorded by Brewer spectrophotometers can be significantly affected by instrument-specific optical and mechanical features. Thus, proper corrections are needed in order to reduce the associated uncertainties to within acceptable levels. The present study aims to contribute to the reduction of uncertainties originating from changes in the Brewer internal temperature, which affect the performance of the optical and electronic parts, and subsequently the response of the instrument. Until now, measurements of the irradiance from various types of lamps at different temperatures have been used to characterize the instruments' temperature dependence. The use of 50 W lamps was found to induce errors in the characterization due to changes in the transmissivity of the Teflon diffuser as it warms up by the heat of the lamp. In contrast, the use of 200 or 1000 W lamps is considered more appropriate because they are positioned at longer distances from the diffuser so that warming is negligible. Temperature gradients inside the instrument can cause mechanical stresses which can affect the instrument's optical characteristics. Therefore, during the temperature-dependence characterization procedure warming or cooling must be slow enough to minimize these effects. In this study, results of the temperature characterization of eight different Brewer spectrophotometers operating in Greece, Finland, Germany and Spain are presented. It was found that the instruments' response changes differently in different temperature regions due to different responses of the diffusers' transmittance. The temperature correction factors derived for the Brewer spectrophotometers operating at Thessaloniki, Greece, and Sodankylä, Finland, were evaluated and were found to remove the temperature dependence of the instruments' sensitivity.
Patrocinador: This article is based upon work from COST Action ES1207 “A European Brewer Network (EUBREWNET)”, supported by COST (European Cooperation in Science and Technology) and from the ENV59-ATMOZ (“Traceability for atmospheric total column ozone”) Joint Research Programme (JRP).
URI : http://hdl.handle.net/20.500.11765/11531
ISSN : 1867-1381
1867-8548
Colecciones: Artículos científicos 2015-2018


Ficheros en este ítem:
  Fichero Descripción Tamaño Formato  
Fountoulakis_Temperat...
1,78 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo del ítem



Los ítems de Arcimis están protegidos por una Licencia Creative Commons, salvo que se indique lo contrario.

Repositorio Arcimis
Nota Legal Contacto y sugerencias