Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.11765/12664
Water vapor retrievals from spectral direct irradiance measured with an EKO MS-711 spectroradiometer—intercomparison with Other Techniques
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGarcía Cabrera, Rosa Deliaes_ES
dc.contributor.authorCuevas Agulló, Emilioes_ES
dc.contributor.authorCachorro, Victoria E.es_ES
dc.contributor.authorGarcía Rodríguez, Omaira Elenaes_ES
dc.contributor.authorBarreto Velasco, Áfricaes_ES
dc.contributor.authorAlmansa Rodríguez, Antonio Fernandoes_ES
dc.contributor.authorRomero Campos, Pedro Migueles_ES
dc.contributor.authorRamos López, Ramónes_ES
dc.contributor.authorPó, Marioes_ES
dc.contributor.authorHoogendijk, Keeses_ES
dc.contributor.authorGross, Jochenes_ES
dc.date.accessioned2021-01-21T15:50:03Z-
dc.date.available2021-01-21T15:50:03Z-
dc.date.issued2021-
dc.identifier.citationRemote Sensing. 2021, 13(30), 350es_ES
dc.identifier.issn2072-4292-
dc.identifier.urihttp://hdl.handle.net/20.500.11765/12664-
dc.description.abstractPrecipitable water vapor retrievals are of major importance for assessing and understanding atmospheric radiative balance and solar radiation resources. On that basis, this study presents the first PWV values measured with a novel EKO MS-711 grating spectroradiometer from direct normal irradiance in the spectral range between 930 and 960 nm at the Izaña Observatory (IZO, Spain) between April and December 2019. The expanded uncertainty of PWV (UPWV) was theoretically evaluated using the Monte-Carlo method, obtaining an averaged value of 0.37 ± 0.11 mm. The estimated uncertainty presents a clear dependence on PWV. For PWV ≤ 5 mm (62% of the data), the mean UPWV is 0.31 ± 0.07 mm, while for PWV > 5 mm (38% of the data) is 0.47 ± 0.08 mm. In addition, the EKO PWV retrievals were comprehensively compared against the PWV measurements from several reference techniques available at IZO, including meteorological radiosondes, Global Navigation Satellite System (GNSS), CIMEL-AERONET sun photometer and Fourier Transform Infrared spectrometry (FTIR). The EKO PWV values closely align with the above mentioned different techniques, providing a mean bias and standard deviation of −0.30 ± 0.89 mm, 0.02 ± 0.68 mm, −0.57 ± 0.68 mm, and 0.33 ± 0.59 mm, with respect to the RS92, GNSS, FTIR and CIMEL-AERONET, respectively. According to the theoretical analysis, MB decreases when comparing values for PWV > 5 mm, leading to a PWV MB between −0.45 mm (EKO vs. FTIR), and 0.11 mm (EKO vs. CIMEL-AERONET). These results confirm that the EKO MS-711 spectroradiometer is precise enough to provide reliable PWV data on a routine basis and, as a result, can complement existing ground-based PWV observations. The implementation of PWV measurements in a spectroradiometer increases the capabilities of these types of instruments to simultaneously obtain key parameters used in certain applications such as monitoring solar power plants performance.es_ES
dc.description.sponsorshipThis study has been performed thanks to regular funds from the State Meteorological Agency of Spain (AEMET) to the World Meteorological Organization (WMO) Commission for Instruments and Methods of Observations (CIMO) Izaña Testbed for Aerosols and Water Vapor Remote Sensing Instruments and the European Community Research Infrastructure Action under the FP7 ACTRIS grant, agreement no. 262254.es_ES
dc.language.isoenges_ES
dc.publisherMultidisciplinary Digital Publishing Institutees_ES
dc.rightsLicencia CC: Reconocimiento CC BYes_ES
dc.subjectSpectral direct irradiancees_ES
dc.subjectSpectroradiometerses_ES
dc.subjectWater vapores_ES
dc.subjectMonte-Carlo methodes_ES
dc.titleWater vapor retrievals from spectral direct irradiance measured with an EKO MS-711 spectroradiometer—intercomparison with Other Techniqueses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://dx.doi.org/10.3390/rs13030350es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/262254es_ES
Colecciones: Artículos científicos 2019-2022


Ficheros en este ítem:
  Fichero Descripción Tamaño Formato  
remotesensing-13-0035...
1,17 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro sencillo del ítem



Los ítems de Arcimis están protegidos por una Licencia Creative Commons, salvo que se indique lo contrario.

Repositorio Arcimis
Nota Legal Contacto y sugerencias