Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.11765/13889
Application of homogenization methods for Ireland's monthly precipitation records: comparison of break detection results
Título : Application of homogenization methods for Ireland's monthly precipitation records: comparison of break detection results
Autor : Coll, JohnDomonkos, PeterGuijarro Pastor, José AntonioCurley, MaryRustemeier, ElkeAguilar, EnricWalsh, SéamusSweeney, John
Palabras clave : ACMANT; AHOPS; Break detection; HOMER; CLIMATOL; Ireland; Homogenization; Precipitation
Fecha de publicación : 2020
Editor: Wiley; Royal Meteorological Society
Citación : International Journal of Climatology. 2020, 40(14), p. 6169-6188
Versión del editor: https://doi.org/10.1002/joc.6575
Resumen : Time series homogenization for 299 of the available precipitation records for the island of Ireland (IENet) was performed. Four modern relative homogenization methods, that is, HOMER, ACMANT, CLIMATOL and AHOPS were applied to this network of station series where contiguous intact monthly records range from 30 to 70 years within the base period 1941–2010. Break detection results are compared between homogenization methods, and coincidences with available documentary information (metadata) were analysed. The lowest (highest) number of breaks were detected with HOMER (ACMANT). Large differences of break frequency were found, namely ACMANT and AHOPS detected 8 times as many breaks than HOMER, while the break frequency with CLIMATOL was intermediate. Also, the ratio of series classified to be homogeneous varies widely between the methods. It is 85% with HOMER, 60% with CLIMATOL, 31% with AHOPS, while only 22% with ACMANT. In a further experiment, all the available time series for Ireland and Northern Ireland, (910 series) were used with ACMANT and CLIMATOL to explore the stability of break frequency for the same 299 series examined in the base experiment. While overall break frequency slightly increased (by 6–13%), the break positions notably changed for individual time series. The number of breaks changed for 59% (23%) of the series with ACMANT (CLIMATOL). For the breaks detected coincidentally by at least three methods including ACMANT and CLIMATOL in the base experiment, the second experiment confirmed the break positions in 86–87% of the breaks. The consequences of these results in relation to the reliability of statistical homogenization are discussed. Sometimes markedly different step functions provide comparable good approaches. However, the accuracy of homogenized time series cannot be related directly to the instability of break detection results.
Patrocinador: Science Foundation Ireland, Grant/Award Number: 16/CW/3801; Irish Environmental Protection Agency, Grant/Award Number: 2012-CCRP-FS.11.
URI : http://hdl.handle.net/20.500.11765/13889
ISSN : 0899-8418
1097-0088
Colecciones: Artículos científicos 2019-2022


Ficheros en este ítem:
  Fichero Descripción Tamaño Formato  
IJC_Coll_2020.pdf
5,5 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo del ítem



Los ítems de Arcimis están protegidos por una Licencia Creative Commons, salvo que se indique lo contrario.

Repositorio Arcimis
Nota Legal Contacto y sugerencias