Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.11765/17331
Evaluation of the uncertainty of the spectral UV irradiance measured by double- and single-monochromator Brewer spectrophotometers
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGonzález, Carmenes_ES
dc.contributor.authorVilaplana Guerrero, José Manueles_ES
dc.contributor.authorRedondas, Albertoes_ES
dc.contributor.authorLópez Solano, Javieres_ES
dc.contributor.authorSan Atanasio, José Maríaes_ES
dc.contributor.authorKift, Richardes_ES
dc.contributor.authorSmedley, Andrew R. D.es_ES
dc.contributor.authorDíaz Rodríguez, Ana Maríaes_ES
dc.contributor.authorBabal, Paveles_ES
dc.contributor.authorJepsen, Nises_ES
dc.contributor.authorGacitúa, Guisellaes_ES
dc.contributor.authorSerrano, Antonioes_ES
dc.date.accessioned2025-11-06T12:47:00Z-
dc.date.available2025-11-06T12:47:00Z-
dc.date.issued2025-
dc.identifier.citationAtmospheric Chemistry and Physics. 2025, 25(21), p. 14131–14152es_ES
dc.identifier.issn1680-7316-
dc.identifier.issn1680-7324-
dc.identifier.urihttp://hdl.handle.net/20.500.11765/17331-
dc.description.abstractBrewer instruments are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in characterising the instruments. This evaluation is essential to determine the quality of the measurements as well as their comparability to other datasets. In this study, eight double- and two single-monochromator Brewers are characterised, and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected because it provides reliable uncertainty estimations and considers the nonlinearity of certain steps in the UV processing algorithm. The combined standard uncertainty depends on the Brewer instrument, varying between 2.5 % and 4 % between 310 and 350 nm. These uncertainties arise primarily from radiometric stability, cosine correction, and the uncertainty of the lamp used during calibration. At shorter wavelengths, the differences between single- and double-monochromator Brewers increase. For example, at 296 nm and a solar zenith angle (SZA) of 40°, the relative uncertainties of single Brewers range between 11 % and 23 %, whereas double Brewers have uncertainties of 3 %–5 %. As the measured wavelength decreases, the correction of stray light (for single Brewers), dark counts, and noise become the dominant sources of uncertainty. These results indicate that the accuracy of fully characterised double Brewers is sufficient for biological studies and trend detection, whereas single Brewers might be limited to wavelengths and SZAs below 305 nm and 70°, respectively.es_ES
dc.description.sponsorshipThis work is part of the PID2023-149390OB-C21 and PID2023-149390OB-C22 R+D+I projects, funded by MICIU/AEI/10.13039/501100011033/ and “ERDF A Way of Doing Europe”.es_ES
dc.language.isoenges_ES
dc.publisherCopernicus Publicationses_ES
dc.rightsLicencia CC: Reconocimiento CC BYes_ES
dc.subjectSolar ultraviolet irradiancees_ES
dc.subjectQuality measurementses_ES
dc.subjectUV measurementses_ES
dc.subjectBrewer spectrophotometerses_ES
dc.titleEvaluation of the uncertainty of the spectral UV irradiance measured by double- and single-monochromator Brewer spectrophotometerses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://doi.org/10.5194/acp-25-14131-2025es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
Colecciones: Artículos científicos 2023-2026


Ficheros en este ítem:
  Fichero Descripción Tamaño Formato  
ACP_Gonzalez_2025.pdf
2,06 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro sencillo del ítem



Los ítems de Arcimis están protegidos por una Licencia Creative Commons, salvo que se indique lo contrario.

Repositorio Arcimis
Nota Legal Contacto y sugerencias