Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.11765/8502
NDACC harmonized formaldehyde time-series from 21 FTIR stations covering a wide range of column abundances
Título : NDACC harmonized formaldehyde time-series from 21 FTIR stations covering a wide range of column abundances
Autor : Vigouroux, CorinneBauer Aquino, Carlos AugustoBauwens, MaiteBecker, CornelisBlumenstock, ThomasDe Mazière, MartineGarcía Rodríguez, Omaira ElenaGrutter, MichelGuarin, CésarHannigan, James W.Hase, FrankJones, NicholasKivi, RigelKoshelev, DmitryLangerock, BavoLutsch, ErikMakarova, MariaMetzger, Jean-MarcMüller, Jean-FrançoisNotholt, JustusOrtega, IvanPalm, MathiasPaton-Walsh, ClarePoberovskii, AnatolyRettinger, MarkusRobinson, JohnSmale, DanStavrakou, TrissevgeniStremme, WolfgangStrong, KimberlySussmann, RalfTe, YaoToon, Geoffrey C.
Palabras clave : Formaldehyde time-series; Fourier transform infrared; Measurements
Fecha de publicación : 2018
Editor: European Geosciences Union
Citación : Atmospheric Measurement Techniques. 2018, 11(9), p. 5049–5073
Versión del editor: https://dx.doi.org/10.5194/amt-11-5049-2018
Resumen : Among the more than 20 ground-based FTIR (Fourier transform infrared) stations currently operating around the globe, only a few have provided formaldehyde (HCHO) total column time series until now. Although several independent studies have shown that the FTIR measurements can provide formaldehyde total columns with good precision, the spatial coverage has not been optimal for providing good diagnostics for satellite or model validation. Furthermore, these past studies used different retrieval settings, and biases as large as 50 % can be observed in the HCHO total columns depending on these retrieval choices, which is also a weakness for validation studies combining data from different ground-based stations. For the present work, the HCHO retrieval settings have been optimized based on experience gained from past studies and have been applied consistently at the 21 participating stations. Most of them are either part of the Network for the Detection of Atmospheric Composition Change (NDACC) or under consideration for membership. We provide the harmonized settings and a characterization of the HCHO FTIR products. Depending on the station, the total systematic and random uncertainties of an individual HCHO total column measurement lie between 12 % and 27 % and between 1 and 11×1014 molec cm−2, respectively. The median values among all stations are 13 % and 2.9×1014 molec cm−2 for the total systematic and random uncertainties. This unprecedented harmonized formaldehyde data set from 21 ground-based FTIR stations is presented and its comparison with a global chemistry transport model shows consistency in absolute values as well as in seasonal cycles. The network covers very different concentration levels of formaldehyde, from very clean levels at the limit of detection (few 1013 molec cm−2) to highly polluted levels (7×1016 molec cm−2). Because the measurements can be made at any time during daylight, the diurnal cycle can be observed and is found to be significant at many stations. These HCHO time series, some of them starting in the 1990s, are crucial for past and present satellite validation and will be extended in the coming years for the next generation of satellite missions.
Patrocinador: This study has been supported by the ESA PRODEX project TROVA (2016–2018) funded by the Belgian Science Policy Office (Belspo).
URI : http://hdl.handle.net/20.500.11765/8502
ISSN : 1867-1381
1867-8548
Colecciones: Artículos científicos 2015-2018


Ficheros en este ítem:
  Fichero Descripción Tamaño Formato  
amt-11-5049-2018-supp...
6,18 MBAdobe PDFVista previa
Visualizar/Abrir
amt-11-5049-2018.pdf
1,31 MBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro completo del ítem



Los ítems de Arcimis están protegidos por una Licencia Creative Commons, salvo que se indique lo contrario.

Repositorio Arcimis
Nota Legal Contacto y sugerencias