Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.11765/9445
Wavelength calibration of Brewer spectrophotometer using a tunable pulsed laser and implications to the Brewer ozone retrieval
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRedondas, Albertoes_ES
dc.contributor.authorNevas, Sauliuses_ES
dc.contributor.authorBerjón, Albertoes_ES
dc.contributor.authorSildoja, Meelis-Maites_ES
dc.contributor.authorLeón-Luis, Sergio Fabiánes_ES
dc.contributor.authorCarreño Corbella, Virgilioes_ES
dc.contributor.authorSantana-Díaz, Danieles_ES
dc.date.accessioned2018-06-29T11:18:04Z-
dc.date.available2018-06-29T11:18:04Z-
dc.date.issued2018-
dc.identifier.citationAtmospheric Measurement Techniques. 2018, 11(6), p. 3759–3768es_ES
dc.identifier.issn1867-1381-
dc.identifier.issn1867-8548-
dc.identifier.urihttp://hdl.handle.net/20.500.11765/9445-
dc.description.abstractIn this contribution we present the wavelength calibration of the travelling reference Brewer spectrometer of the Regional Brewer Calibration Center for Europe (RBCCE) at PTB in Braunschweig, Germany. The wavelength calibration is needed for the calculation of the ozone absorption coefficients used by the Brewer ozone algorithm. In order to validate the standard procedure for determining Brewer’s wavelength scale, a calibration has been performed by using a tunable laser source at PTB in the framework of the EMRP project ENV59 ATMOZ “Traceability for the total column ozone”. Here we compare these results to those of the standard procedure for the wavelength calibration of the Brewer instrument. Such a comparison allows validating the standard methodology used for measuring the ozone absorption coefficient with respect to several assumptions. The results of the laser-based calibrations reproduces those obtained by the standard operational methodology and shows that there is an underestimation of 0.8 % of the ozone absorption coefficients due to the use of the parametrized slit functions.es_ES
dc.description.sponsorshipThis work has been supported by the European Metrology Research Programme (EMRP) within the joint research project ENV59 “Traceability for atmospheric total column ozone” (ATMOZ). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.es_ES
dc.language.isoenges_ES
dc.publisherEuropean Geosciences Uniones_ES
dc.rightsLicencia CC: Reconocimiento CC BYes_ES
dc.subjectBrewer spectrophotometeres_ES
dc.subjectBrewer calibrationes_ES
dc.subjectOzonees_ES
dc.titleWavelength calibration of Brewer spectrophotometer using a tunable pulsed laser and implications to the Brewer ozone retrievales_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://dx.doi.org/10.5194/amt-11-3759-2018es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
Appears in Collections:Artículos científicos 2015-2018


Files in This Item:
  File Description SizeFormat 
amt-11-3759-2018.pdf
1,18 MBAdobe PDFThumbnail
View/Open
Show simple item record



Items in Arcimis are protected by Creative Commons License, unless otherwise indicated.

Arcimis Repository
Nota Legal Contacto y sugerencias